beautypg.com

Precision Trading 60 R3.0 User Manual

Page 17

background image

Operator Manual, Supercharger 60

R3.0

Page 17 of 62

3.5 DIGITAL PANEL METERS

3.5.1. VOLTMETER:

3.5.1.1. Accuracy (system): ±0.25% of reading, ±0.1V in the 200V scale,

±0.01V in the 20V scale, ±0.005V in the 2V scale.

3.5.1.2. Input impedance: 1 M-OHM.

3.5.1.3. Scale 2V, 20V and 200V (1.999V, 19.9V and 199.9V) for external

measurements and 20V and 200V for internal (battery) measurements.

3.5.2. AMMETER:

3.5.2.1. Accuracy (system): ±0.5% of reading, ±0.1A

3.5.2.2. Scale: 200A (199.9A)

3.5.3. SHUNT:

3.5.3.1. Accuracy: ±0.25%

3.5.3.2. Output: 1mV/A (100mV / 100A)

3.6 FUSES and BREAKERS (Other than charge and discharge current limiters)

3.6.1. Mains: Dual Magnetic Circuit Breaker

3.6.2. Electronics and digital panel meters: 1/4A SLO BLO.