Appendix D

67

Appendix D

Knife MFG Guideline

Solenoid Trigger Setting

+.000

-.020

1. After the clutch and actuator is mounted to the knife, attach the solenoid assembly to the inside

support using two 6-32 x 3/8 cap screws, flat washers, and lock washers. Make sure the plunger
moves freely and does not bind. Motor and faceplate must be mounted also.

2. Check the gap between the actuator and the top of the pin on the clutch as shown in drawing.

The plunger should be pushed in to make the measurement.

Other hints if there is still a problem:

• If the gap is greater then .047”, an old solenoid bracket is being used. Replace (P/N 357003) or

slot the bracket.

• If plunger binds, the solenoid is not parallel with the base of the bracket that mounts to the knife

support, and/or the actuator slot is bottoming out on the roll pins that are on the plunger. Make
adjustment or replace the bracket.