Printronix Series 5 User Manual
Page 78
Configuration Menus
4–25
Optimized Ratio
This option selects different bar code ratios for certain bar codes including Code 39
and Interleaved 2 of 5. It is included for compatibility with the IGP–X00 printers.
•
Enable. Select the alternate bar code ratios.
•
Disable. Use standard bar code ratios.
Interleaved 2/5 Selection
This option is added to be compatible with a special IGP-X00 customization.
Usually, if Interleaved 2/5 bar codes have an odd number of digits, a leading zero
is inserted in front of the data. However, this special IGP-X00 customization adds
a space character at the end of the bar code instead.
•
Leading Zero. A leading zero is inserted in front of the data.
•
Trailing Space. A space is inserted at the end of the data instead of a
leading zero.
•
X2 DPD. When selected, I–2/5 bar code with a magnification X2 will use
the specially configured ratios 3:3:6:5 rather than 3:6:9:12 for
compatibility issues.
True Form Slew
This option is related to slewing within forms when using the P–Mode command.
Customers with new applications are advised to keep this option enabled.
•
Enable. Form length is accurate according to the form length parameter
in the CREATE command.
•
Disable. Form length is IGP–X00 compatible when using P–Mode.
Printer PI Line
This option enables the IGP to send down PI instructions to the printer to slew
the form.
•
Enable. Send down the PI instructions to the printer (LinePrinter Plus)
during form slew. This is IGP–X00 compatible.
•
Disable. Do not send PI instructions to the printer. LFs are sent instead.