Technical information, English – Panasonic PT-DW8300U User Manual
Page 116
Technical Information
116
- ENGLISH
Appendix
J
When WEB Control administrator rights password is not set
(Non-protect mode)
Obtain the IP address and port number (Initial set value = 1024) of the projector and
1 )
make a request for connection to the projector.
You can obtain both IP address and port number from the menu screen of the projector.
IP address :
Obtain from MAIN MENU
⇒ [NETWORK] ⇒ [NETWORK STATUS]
Port number : Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK CONTROL] ⇒ [COMMAND PORT]
There is a response from the projector.
2 )
Response data
Data section
Blank
Mode
Termination
symbol
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘0’
0x30
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
Mode : 0 = Non-protect mode
Transmit by the following command format.
Transmitted data
Header
Data section
Termination
symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Receive data
Header
Data section
Termination
symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Error response
Error message
Termination symbol
“ERR1”
“ERR2”
“ERR3”
“ERR4”
“ERR5”
“ERRA”
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
(CR)
0x0d
4 bytes
1 byte