beautypg.com

Technical information, English – Panasonic PT-DW8300U User Manual

Page 116

background image

Technical Information

116

- ENGLISH

Appendix

J

When WEB Control administrator rights password is not set

(Non-protect mode)

Obtain the IP address and port number (Initial set value = 1024) of the projector and

1 )

make a request for connection to the projector.

You can obtain both IP address and port number from the menu screen of the projector.
IP address :

Obtain from MAIN MENU

⇒ [NETWORK] ⇒ [NETWORK STATUS]

Port number : Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK CONTROL] ⇒ [COMMAND PORT]

There is a response from the projector.

2 )

Response data

Data section

Blank

Mode

Termination

symbol

“NTCONTROL”

(ASCII string)

‘ ’

0x20

‘0’

0x30

(CR)

0x0d

9 bytes

1 byte

1 byte

1 byte

Mode : 0 = Non-protect mode

Transmit by the following command format.
Transmitted data

Header

Data section

Termination

symbol

‘0’

0x30

‘0’

0x30

Control command

(ASCII string)

(CR)

0x0d

1 byte

1 byte

Undefined length

1 byte

Receive data

Header

Data section

Termination

symbol

‘0’

0x30

‘0’

0x30

Control command

(ASCII string)

(CR)

0x0d

1 byte

1 byte

Undefined length

1 byte

Error response

Error message

Termination symbol

“ERR1”

“ERR2”

“ERR3”

“ERR4”

“ERR5”

“ERRA”

Undefined control command

Out of parameter range

Busy state or no-acceptable period

Timeout or no-acceptable period

Wrong data length

Password mismatch

(CR)

0x0d

4 bytes

1 byte

This manual is related to the following products: