Network menu, English, Error information page – Panasonic PT-DW8300U User Manual
Page 100: When [failed] has appeared for an item
NETWORK menu
100
- ENGLISH
Settings
Error information page
J
When “Error (Detail)” is displayed on the status information screen, click it to display the error details.
Depending on the nature of the error, the projector may be placed in the standby mode for its own
z
protection.
When [FAILED] has appeared for an item
Q
Parameter
Description
MAIN CPU BUS
Trouble has occurred in the microcomputer circuitry. Consult your dealer.
FAN
Trouble has occurred in the fan or its drive circuit. Consult your dealer.
INPUT AIR TEMPERATURE
The input air temperature is too high. It may be that the projector is being used in an
operating environment where the temperature is high such as near a heating appliance.
OPTICS MODULE TEMPERATURE
The temperature inside the projector is high. It may be that the projector is being used
in an operating environment where the temperature is high such as near a heating
appliance.
AROUND LAMP TEMPERATURE
The temperature around the lamp is too high. It may be that the projector’s ventilation
holes are blocked.
LAMP1 REMAIN TIME
The lamp runtime has exceeded the prescribed cumulative time, and it is now time to
replace the lamp.
LAMP2 REMAIN TIME
LAMP1 STATUS
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
LAMP2 STATUS
APERTURE (CONTRAST-SHUTTER)
Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
INPUT AIR TEMP. SENSOR
Trouble has occurred in the sensor used to detect the input air temperature.
Consult your dealer.
OPTICS MODULE TEMP. SENSOR
Trouble has occurred in the temperature detection sensor inside the projector.
Consult your dealer.
AROUND LAMP TEMP. SENSOR
Trouble has occurred in the sensor used to detect the exhaust air temperature.
Consult your dealer.
BATTERY
The backup battery has been run out. Consult your dealer.
AIRFLOW SENSOR
Trouble has occurred in the sensor used to detect the airflow volume.
Consult your dealer.
COVER OPEN
The lamp unit cover is not attached securely. Check the lamp unit compartment.
ACF UNIT
The air cleaning filter (ACF) is not installed or trouble has occurred. (
FILTER REMAIN
The filter remaining is getting less. (
BRIGHTNESS SENSOR
Trouble has occurred in the brightness sensor. If the problem cannot be corrected by
turning the power off and on, consult your dealer.
AC POWER
AC power supply voltage input has dropped. Check that there is sufficient
electrical wiring capacity for the projector’s power consumption requirements.
Note
The ACCESS ERROR INFORMATLION/ACCESS INFORMATION displays the past several thousand accesses/requests.
z
If many accesses/requests are made at a time, some of them may not be found in the information.
Check the ACCESS ERROR INFORMATION/ACCESS INFORMATION regularly.
z
OK:
Normal operation
FAILED: Occurrence of trouble