Installation

47

Model 3088 Series User Manual

3 • RocketLink-G installation

Connect twisted pair (120 ohm) to E1 network

The Model 3088/K is equipped with a single RJ-48C jack for connections to a 120 ohm twisted pair E1 net-
work interface. If your E1 network terminates via RJ-48C, use the diagram below and the table following it to
make the proper connections. The connector pinout and signals are shown in

figure 13

.

Figure 13. 120 Ohm RJ-48C E1 interface

Use the following connection diagram to connect the 120-ohm E1 network channel.

\

Figure 14. RJ-45 cable diagram for E1 connection

Connecting dual coaxial cable (75 ohm) to E1 network

The Model 3088/K is also equipped with dual female BNCs (TX and RX) for connection to a 75 ohm dual
coax E1 network interface. If your E1 network terminates via dual coaxial cable, use

figure 15

to make the

proper connections.

The interconnecting cables shall be acceptable for external use
and shall be rated for the proper application with respect to volt-
age, current, anticipated temperature, flammability, and
mechanical serviceability.

1

2

3

4

5

6

7

8

1
2
3
4
5
6
7
8

(RX) Receive (Ring)
(RX) Receive (Tip)
Shield
(TX) Transmit (Ring)
(TX) Transmit (Tip)
Shield
No connection
No connection

Signal Name

RJ-48C Jack

RJ-48C Cable (8-Wire)

E1 (G.703/G.704)

Network signal

3088/K

Signal

Pin #

RX (Ring)

RX (Tip)

Shield

TX (Ring)

TX (Tip)

Shield

1
2
3
4
5
6

TX (Ring)
TX (Tip)
Shield
RX (Ring)
RX (Tip)
Shield

CAUTION