Installation – Lincoln Electric PIPELINER 200 User Manual
Page 46

INSTALLATION
AAA-2
AAA-2
DC CURRENT RANGE
Fine Adjustment in each Range
40-300 Amps
DUTY CYCLE
60%
60%
RATED DC OUTPUT*
VOLTS @ RATED AMPS
Lincoln Plus Rating
40V @ 200A
NEMA Rating
28V @ 200A
PIPELINER® 200G
1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to
rated capacity. When welding, available auxiliary power will be reduced.
Make/Model
Description
Speed (RPM)
Displacement
Ignition
Capacities
cu. in. (Ltrs.)
System
High Idle 1600
Delco Voyager Fuel: 15gal.(57L)
4 Cylinder
High Energy
GM
4 Cycle
Oil: 4.5Qts.(4.3L)
3.0 Liter
Full Load 1600
Distributor Type
Pipeliner® 200G
183.0(3.0)
Electronic
(K6090-7)
46 HP @
1600 RPM
Low Idle 1360
INPUT - GASOLINE ENGINE
RATED OUTPUT - WELDER
HEIGHT
WIDTH
DEPTH
WEIGHT
40.94** in.
24.00 in.
68.16in.
1039.9 mm
609.6 mm
1731.0 mm
1295.0 lbs. (587kg.)
**Top of enclosure, add 4.6” (116.8mm) for exhaust
OUTPUT - GENERATOR
Auxiliary Power
1
1.75 kW, 15 Amps @ 120V DC
PHYSICAL DIMENSIONS
ENGINE OPERATING LOAD
FUEL CONSUMPTION
Coolant: 9.9 Qts.
(9.4L)
TECHNICAL SPECIFICATIONS - Pipeliner® 200G (K6090-7)
DESCRIPTION
200 Amp DC Welder
All Copper Windings
Pure DC Power
Generator
Low Idle (1360 RPM)-No Load
High Idle (1600 RPM)-No Load
DC Auxiliary-128 Volts-15 Amps-1600 RPM
50 Amps @ 38 Volts @ 60% Duty Cycle
100 Amps @ 34 Volts @ 60 % Duty Cycle
150 Amps @ 29 Volts @ 60% Duty Cycle
200 Amps @ 40 Volts @ 60 % Duty Cycle
.7 gal/hr (2.8 ltrs/hr)
.8 gal/hr (3.1 ltrs/hr)
1.1 gal/hr (4.0 ltrs/hr)
1.04 gal/hr (3.94 ltrs/hr)
1.12 gal/hr (4.25 ltrs/hr)
1.15 gal/hr (4.37 ltrs/hr)
1.34 gal/hr (5.07 ltrs/hr)