Figure 10-1 Wiring Diagram

10

Diagrams

X1-7

OR

OR

BR

PR

OR

BR

BR

PR

PR

CN2-4

CN2-1

CN1-5

CN1-6

CN1-3

CN1-4

CN1-1

CN1-2

K1

K2

K3

RELAY

BOARD

ON/OFF

SWITCH

JUNCTION

BOX

BK

W

1 2 3 4 5

G

R

R W

3.5A

R

T

W

BK

Y

BL

KB 801

ONLY

BLOWER

-T

HIGH LIMIT SENSOR S1b

OPERATING SENSOR S1a

INLET SENSOR S2

FLUE SENSOR S3a

FLUE SENSOR S3b

INTEGRATED

CONTROL

BK

Y

GAS VALVE
@24VAC

SPARK

ROD

TRANSFORMER

TR2

G

HIGH VOLTAGE SPARK LEAD

CAUTION

FLAME SENSOR

P/BK

Y

W/R

X1-3

X1-4

X1-2

X1-6
X1-5

X1-8

X1-1

X5-7

X5-16

X5-8

X5-15

X5-9

X5-1

X5-2

X5-10

X5-11

X5-4

X5-12

X5-6

X5-5

X5-13

X5-14

X2-2

X2-1

O-TEMP HEX SW

BLOCKED DRAIN SWITCH

O

Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.

WIRING DIAGRAM

LBL20116 REV E

BOX DEPICTS

OPTIONAL ITEMS

CN2-2

CN2-3

DHW
PUMP

BOILER
PUMP

SYSTEM
PUMP

120V
SUPPLY

L

N

GND

L

N

X-7

BOX DEPICTS

DUAL SENSOR

SINGLE HOUSING

MODBUS BOARD

MTR-01

X

6-3

X

6-2

X

6-1

X

6-4

X9-1
X9-2
X9-3
X9-4

X4-1
X4-2
X4-3
X4-4

X5-1
X5-2

X1-1
X1-2
X1-3

BK

W

G

R BL G

-T

-T

-T

-T

SHIELD

GROUNDING

JUMPER

O

GY

G

R/BK

W/BK

GY

PR

1 2

G

3

HIGH VOLTAGE

LOW VOLTAGE

120 VAC

AIR PRESSURE SWITCH

P

O/BK

ALARM

CONTACTS

RUN-TIME

CONTACTS

24 VAC LOUVER

RELAY COIL

LOUVER

PROVING SWITCH

GAS PRESSURE

SWITCH

FLOW

SWITCH

TANK

THERMOSTAT

11
12
13
14
15
16
17
18
19
20

SYSTEM

SENSOR

OUTDOOR

SENSOR

TANK

SENSOR

CASCADE

A

B

SHIELD

SHIELD

0-10V

+

-

BMS

IN

0-10V

+

-

SYS PUMP

IN

0-10V

+

-

BLR PUMP

OUT

0-10V

+

-

RATE

OUT

MODBUS

OPTION

A

B

SHIELD

SHIELD

LOW

WATER

CUT-OFF

24 VAC

COM

1
2
3
4
5
6
7
8
9

10

21
22
23
24
25
26
27
28
29
30
31
32

33
34
35
36
37
38
39
40
41
42
43
44

CN7-1
CN7-2
CN7-3
CN7-4

CONNECTION BOARD

CN8

-1

CN8

-2

CN8

-3

R BL G

BELL J

U

M

P

E

R

ALAR

M

BELL

SILE

N

C

IN

G S

W

ITC

H

HEAT/LOOP

DEMAND

3

HEAT/LOOP

DEMAND

2

HEAT/LOOP

DEMAND

1

CN5-1
CN5-8
CN5-2
CN5-9
CN5-3
CN5-10
CN5-11
CN5-4
CN5-5
CN5-14
CN5-12
CN5-6
CN5-13
CN5-7

BK
BK
BK
BK
BK

BK
BK
BK
BK
BK

BK
BK
BK
BK

CN6

X6

X4-7

X4-14

X4-6

X4-13

X4-5

X4-12
X4-11

X4-4
X4-3
X4-8

X4-10

X4-2
X4-9
X4-1

Outdoor Knight XL Installation & Operation

Manual