System-error log messages – Lenovo TS100 User Manual
Page 253
System-error log messages
A system-error log is generated by both the Remote Supervisor Adapter II SlimLine
adapter and the mini-BMC. The system-error log can contain messages of three
types:
Information
Information messages do not require action; they record significant
system-level events, such as when the server is started.
Warning
Warning messages do not require immediate action; they indicate
possible problems, such as when the recommended maximum
ambient temperature is exceeded.
Error
Error messages might require action; they indicate system errors,
such as when a fan is not detected.
Each message contains date and time information, and it indicates the source of
the message (POST/BIOS or the service processor).
In the following example, the system-error log message indicates that the server
was turned on at the recorded time.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Date/Time: 2002/05/07 15:52:03
DMI Type:
Source: SERVPROC
Error Code: System Complex Powered Up
Error Code:
Error Data:
Error Data:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
The following table describes the possible system-error log messages and
suggested actions to correct the detected problems.
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434,” on page 37
to determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
System-error log message
Action
A system NMI was detected
Make sure that the system software is operating correctly and does
not conflict with other software; the system software has created a
software NMI, or pressing the NMI button has created a service
NMI.
Alert accepted by remote system x; type:y, ID:z
Information only.
Alert accepted from system x; type:y, sender’s
ID:z
Information only.
Alert ID x will be retried by sender; when
accepted by a remote system, it will have a
different ID
Information only.
Alert not accepted by remote system x; type:y,
ID:z
Information only.
Alert not accepted from system x; type:y,
sender’s ID:z
Information only.
Chapter 5. Diagnostics
235