beautypg.com

Power supply leds – Lenovo TS100 User Manual

Page 179

background image

If an error occurs, view the server LEDs in the following order:

1. Check the front-panel assembly on the front of the server. If the system-error

LED is lit, it indicates that an error has occurred.

2. Check the front and rear of the server to determine whether any component

LEDs are lit.

3. Remove the server cover and look inside the server for lit LEDs. Certain

components inside the server have LEDs that will be lit to indicate the location
of a problem. For example, a DIMM error will light the LED next to the failing
DIMM on the system board.

Look at the system service label on the top of the server, which gives an
overview of internal components. This information can often provide enough
information to correct the error.

Power supply LEDs

The following minimum configuration is required for the server to start:
v

One microprocessor

v

One 512 MB DIMM

v

One power supply

v

Power backplane

v

Power cord

v

System board

The following is an illustration of the connectors, AC power supply LED

1 , and DC

power supply LED

2 on the rear of the hot-swap and non-hot-swap server

models.

Chapter 5. Diagnostics

161

This manual is related to the following products: