beautypg.com

Lenovo TS100 User Manual

Page 236

background image

Table 12. Diagnostic messages (continued)

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

v

See Chapter 3, “Parts listing, ThinkServer TS100 Machine Types 6431, 6432, 6433, and 6434,” on page 37 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.

Message
number

Component

Test

State

Description

Action

202-901-xxx

Memory

Memory Stress Test

Failed

Test failure.

1. Run the standard Diagnostic memory

diagnostic to validate all memory.

2. Make sure that the Diagnostic code is

at the latest level. For the latest level of
Diagnostic code, go to:
http://www.lenovo.com/support.

3. Turn off the system and disconnect it

from power.

4. Reseat the DIMMs.

5. Reconnect the system to power and

turn on the system.

6. Run the test again.

7. Run the standard Diagnostic memory

diagnostic to validate all memory.

8. If the problem remains, collect the data

from the Diagnostic event log and send
it to Lenovo Service. For information
about contacting Lenovo Service, see
http://www.lenovo.com/support.

218

ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual

This manual is related to the following products: