beautypg.com

Removing the microprocessor and fan sink – Lenovo TS100 User Manual

Page 136

background image

Removing the microprocessor and fan sink

To remove the microprocessor and fan sink, complete the following steps:

1. Read the safety information that begins on page vii and “Installation guidelines”

on page 57.

2. Turn off the server and all attached devices; then, disconnect all power cords

and external cables.

3. Turn the server on its side so that it is lying flat, with the cover facing up.

4. Unlock and remove the side cover (see “Removing the side cover” on page

62).

5. Disconnect any cables that impede access to the fan sink and microprocessor.

Attention:

The fan-sink retention lever is spring-loaded when the fan sink is

in place. Releasing the lever too quickly or allowing it to spring upward can
damage the fan sink and surrounding components.

6. Remove the fan sink from the microprocessor:

a. Disconnect the fan-sink cable from the system board.

b. Release the fan-sink retention lever by pressing down on the end, moving

it to the side and slowly releasing it to the open (up) position.

Important: Be careful when you handle the microprocessor and fan sink.
If the microprocessor and fan sink will be reused, do not contaminate the
thermal material between them.

1 Orientation indicators
2 Fan-sink retention lever

118

ThinkServer TS100 Types 6431, 6432, 6433, and 6434: Hardware Maintenance Manual