KTI Networks KS-2262 User Manual
Page 94

92
 
 
Function name: 
GVRP Config
Function description:
In the function of GVRP Config, it is used to configure each port’s GVRP 
operation mode, in which there are seven parameters needed to be configured 
described below. 
Parameter description:
GVRP State Setting:
This function is simply to let you enable or disable GVRP function. You 
can pull down the list and click the 
“Enable” or “Disable”. Then, click the 
take effect immediately. 
Join Time:
Used to declare the Join Time in unit of centisecond. Valid time range: 
20 –100 centiseconds, Default: 20 centisecond. 
Leave Time:
Used to declare the Leave Time in unit of centisecond. Valid time range: 
60 –300 centisecond, Default: 60 centisecond. 
Leave All Time:
A time period for announcement that all registered device is going to be 
de-registered. If someone still issues a new join, then a registration will 
be kept in the switch. Valid range: 1000-5000 unit time, Default: 1000 unit 
time. 
Default Applicant Mode:
The mode here means the type of participant. There are two modes, 
normal participant and non-participant, provided for the user’s choice. 
Normal:
It is Normal Participant. In this mode, the switch participates 
normally in GARP protocol exchanges. The default setting is 
Normal. 
Non-Participant:
It is Non-Participant. In this mode, the switch does not send or 
reply any GARP messages. It just listens messages and 
reacts for the received GVRP BPDU. 
Default Registrar Mode:
The mode here means the type of Registrar. There are three types of 
parameters for registrar administrative control value, normal registrar, 
fixed registrar and forbidden registrar, provided for the user’s choice. 