U

sing and

C

aring for

Y

our

C

ooktop

Adjusting the height of top burner
flames

w

WARNING

Carbon Monoxide Poisoning Hazard

Do not operate with a yellow flame.

Doing so can result in death,
heart attack, or convulsions.

The LO burner flame should be a steady
blue flame approximately

1

4

inch (6 mm)

high. It can be adjusted using the adjustment
screw in the center of the valve stem. The
valve stem is located directly underneath the
control knob.

To adjust the flame height follow the
instructions below:

1.

Turn the control knob to “LO.”

2.

Remove the control knob. (If there is not
an adjustment screw underneath the knob
the flame height is not adjustable.)

3.

Hold the valve stem with a pair of pliers.
The screw is located in the center of the
valve stem. Use a small flat head screw-
driver to turn the screw until the flame is
the proper size.

4.

Replace the control knob.

5.

Test the flame by turning the control from
“LO” to “HI,” checking the flame at each
setting.

Adjustment screw

Valve stem

Low flame

High flame

Port

Port