Replacing the feed roller assembly – Kodak A-61602 User Manual
Page 83
80
A-61602 January 2008
Replacing the feed roller
assembly
1. Open the scanner cover.
2. Remove the input tray by pulling it forward and lifting it out of
position. Set it aside.
3. Rotate the orange tab upward to release the feed roller assembly.
4. Lift the feed roller assembly up and out of the scanner.