Figure 3. option 1 installation (side view) – Siemens 1015N-2MFM-1A User Manual
Page 8
4
1015N-2MFM-1A
CAUTION: Do not connect a serial data cable to J1 on the 1015N-2M Modem Card or
damage to the Modem Card and flowmeter may result.
4. Loosen the four captive screws (1) at the corners of the 1010N-2 module (7) and carefully
lift out the module disengaging it from the connector on the 1010N-5 module (2).
5. Lift off the shield (3) covering the 1010N-5 module (2).
6. Leave the 1010N-5 module in place. Check to assure that the four corner standoffs (4) are
securely threaded in place.
ASSEMBLY (see Figure 3)
7. Install shield (5) supplied with the 1015N-2M-MK1 mounting kit and cover the 1010N-5
module. Note: This shield replaces the shield removed in Step 5 above.
8. Remove the four captive screws (1) from the 1010N-2 module loosened in Step 4 above.
Install standoffs (6) from mounting kit in the vacant positions.
9. Install the 1010N-2 module (7) carefully engaging connector P1 to the 1010N-5 module (2).
Secure by threading the four standoffs (6) installed in Step 5 above with their mates on
the 1010N-5 module.
10. Check for properly alignment of P1.
Figure 3. Option 1 Installation (side view)
(11) 1010N-2 I/O
Module Cover
(9) 1010N-2 I/O Module
(12) Captive Screw
(1) 1010N-2 Captive Screws
(3) 1010N-5 Analog Module Shield
(4) Threaded Standoffs
(2) 1010N-5 Analog Module Assy
START VIEW
(11) 1010N-2 I/O
Module Cover
(9) 1015N-2M
Modem Card
(7) 1010N-2
I/O Module
(12) Captive Screw
(10) Cover Mount
Standooff
(4) Threaded Standoffs
(6) Threaded Standoff
(5) 1010N-5 Analog
Module Shield
(2) 1010N-5 Analog Module Assy
FINISH VIEW
Serial Data Cable - Not
used with 1015N-2M
Modem Card.