1015N-2MFM-1A
4. Loosen the four captive screws (1) at the corners of the 1010N-8M module (2) and carefully
lift out the module disengaging it from the ribbon cable connecting it to the 1010N-2M
module (3).
5. Leave the 1010N-2M module in place. Check to assure that the four corner standoffs (4)
are securely threaded in place.
CAUTION: Do not connect a serial data cable to J1 on the 1015N-2M Modem Card or
damage to the Modem Card and flowmeter may result.
ASSEMBLY (see Figure 5)
6. Remove the four captive screws (1) from the 1010N-8M module (2) in Step 4 above and
discard. Install standoffs (5) from the mounting kit in the vacant positions, replacing the
four 4-40 hex nuts to secure the standoff.
7. Install the 1010N-8M module (2) carefully engaging the ribbon cable connector (6) and
dressing the cable for the best fit. Secure cable by threading the four standoffs (5) installed
in Step 6 above with their mates on the 1010N-2M module (3).
Figure 5. Option 3 Installation (side view)
START VIEW
(10) 1010N-8M I/O
Module Cover
(11) Captive Screw
(2) 1010N-8M I/O Module
(3) 1010N-2M
Analog Module
(1) Captive Screws
(4) Threaded Standoffs
System Computer Shield
FINISH VIEW
System
Computer
Shield
Dress Ribbon Cable
Between Modules
(6) 1010N-8M
(9) 1010N-2M
with Shield
(4) Threaded Standoffs
(5) Threaded Standoffs
(3) 1010N-2M
Analog Module
(2) 1010N-8M I/O Module
(8) Cover Mount Standoff
(11) Captive Screw
(10) 1010N-8M I/O
Module Cover
(7) 1010N-8M I/O Module
Serial Data Cable - Not
used with 1015N-2M
Modem Card.