background image

Chapter 3

Sun StorEdge A3500/A3500FC Configurations

3-9

3.1.4

3x15 Configuration

The 3x15 configuration includes three controller modules with a total of fifteen
StorEdge D1000 disk arrays combined in a 2x7 cabinet or a 1x8 cabinet.

3.1.4.1

Option Switch

All disk arrays are on a single bus and should be set as described in Section 3.1.2.1
“Option Switch” on page 3-5.

3.1.4.2

Module ID Switch

Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to

TABLE 3-4

and

TABLE 3-5

.

TABLE 3-4

3x15 Module ID Switch Settings in the 2x7 Cabinet

Disk Array Number

Module ID Setting

7 (Top)

5

6

4

5

3

4

2

3

1

2

1

1 (Bottom)

2

TABLE 3-5

3x15 Module ID Switch Settings in the 1x8 Cabinet

Disk Array Number

Module ID Setting

8 (Top)

5

7

4

6

3

5

2

4

1

3

5

2

4

1 (Bottom)

3