beautypg.com

2 module id switch, Table32 1x5 module id switch settings, 3 scsi jumper cables and terminators – Sun Microsystems Sun StorEdge A3500FC User Manual

Page 38: Module id switch, Scsi jumper cables and terminators

background image

3-6

Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999

3.1.2.2

Module ID Switch

Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to

TABLE 3-2

.

3.1.2.3

SCSI Jumper Cables and Terminators

All Sun StorEdge D1000 disk arrays in this configuration should have SCSI jumper
cables between the middle SCSI connectors (IN/OUT-1 and IN/OUT-2) and a
differential SCSI terminator in the far right SCSI connector (IN/OUT-2). This
configuration is shown in

FIGURE 3-15

.

TABLE 3-2

1x5 Module ID Switch Settings

Disk Array Number

Module ID Setting

5 (Top)

5

4

4

3

3

2

2

1 (Bottom)

1