beautypg.com

2 module id switch, Table33 2x7 module id switch settings, 3 scsi jumper cables and terminators – Sun Microsystems Sun StorEdge A3500FC User Manual

Page 40: Module id switch, Scsi jumper cables and terminators

background image

3-8

Sun StorEdge A3500/A3500FC Hardware Configuration Guide • December 1999

3.1.3.2

Module ID Switch

Ensure that the module IDs for the StorEdge D1000 disk arrays are set according to

TABLE 3-3

.

In this configuration (from the front of the expansion cabinet), the following occurs:

Controller module A controls the right side of disk arrays 1 through 3 and all of
disk arrays 4 and 5.

Controller module B controls the left side of disk arrays 1 through 3 and all of
disk arrays 6 and 7.

This configuration is shown in

FIGURE 3-17

.

3.1.3.3

SCSI Jumper Cables and Terminators

The top four StorEdge D1000 disk arrays should have SCSI jumper cables between
the middle SCSI connectors (IN/OUT-1 and IN/OUT-2) and a differential SCSI
terminator in the far right SCSI connector (IN/OUT-2).

The bottom three StorEdge D1000 disk arrays should have differential SCSI
terminators on the inside IN/OUT-1 and IN/OUT-2 SCSI connectors. This
configuration is shown in

FIGURE 3-17

.

TABLE 3-3

2x7 Module ID Switch Settings

Disk Array Number

Module ID Setting

7 (Top)

5

6

4

5

5

4

4

3

3

2

2

1 (Bottom)

1