Samsung SRP-500 User Manual
Page 35

61
GS ( A pL pH n m
[Name]
Execute test print
[Format]
ASCII
GS (
A
pL
pH
n
m
Hex
1D
28
41
pL
pH
n
m
Decimal
29
40
65
pL
pH
n
m
[Range]
(pL + (pH ×256) ) = 2 (where pL = 2, pH = 0)
0 ≤ n ≤ 2, 48 ≤ n ≤ 50
1 ≤ m ≤ 3, 49 ≤ n ≤ 51
[Description]
• Executes a test print with a specified test pattern on a specified paper.
• pL and pH specifies the number of the parameter such as n,m to (pL + (pH
×
256) ) bytes.
• n specifies the paper to be tested.
n
Paper
0, 48
Basic sheet (paper roll)
1, 49
2, 50
Paper roll
• m specifies a test pattern.
n
Test pattern
1, 49
Hexadecimal dump
2, 50
Printer status print
3, 51
Rolling pattern print
[Notes]
• When the hexadecimal dump is printed by this command, the data which
is transmitted after the command may not be printed because the printer
clears the receive buffer. To avoid this, transmit data from the host after
the printer prints the starting message of the hexadecimal dump.
• This command is enabled only when processed at the beginning of a line
in standard mode.
62
GS I n
[Name]
Transmit printer ID
[Format]
ASCII
GS
I
n
Hex
1D
49
n
Decimal 29
73
n
[Range]
1 ≤ n ≤ 3
[Function]
Transmits the printer ID specified by n as follows:
Bit
Printer ID
Specification
ID (hexadecimal)
1,49
Printer model ID
SRP-500 series See table
0D
2,50 Type
ID
below
3,51
ROM version ID
ROM version
n = 2, Type ID
Bit
Off/On
Hex
Decimal
Function
Off
00
0
Two-byte character code not supported.
0
On
01
1
Two-byte character code supported.
Off
00
0
Auto cutter not equipped.
1
On 02 2 Auto
cutter
equipped.
2 - - -
Undefined.
3 - - -
Undefined.
4
Off
00
0
Not used. Fixed to Off.
5 - - -
Undefined.
6 - - -
Undefined.
7
Off
00
0
Not used. Fixed to Off.
[Notes]
• The printer ID is transmitted when the data in the receive buffer is
developed. Therefore, there may be a time lag between receiving this
command and transmitting the status, depending on the receive buffer
status.
[Reference]