Dip switch settings, 5. you want to check a software program, 1. setting the dip switches – Samsung SRP-500 User Manual
Page 13

17
2-5. You want to check a software program.
• Hexadecimal Dump
This feature allows experienced users to see exactly what data is coming
to the printer. This can be useful in finding software problems. When you
turn on the hexadecimal dump function, the printer prints all commands
and other data in hexadecimal format along with a guide section to help
you find specific commands.
To use the hexadecimal dump feature, follow these steps:
1) After you make sure that the printer is off, open the front cover of the
printer.
2) Hold down the Feed button while you turn on the printer.
3) Close the front cover.
4) Run any software program that sends data to the printer. The printer
prints “Hexadecimal Dump” and then all the codes it receives in a two –
column format. The first column contains the hexadecimal codes and
the second column gives the ASCII characters that correspond to the
codes.
• A period(.) is printed for each code that has no ASCII equivalent.
5) When the printing finishes, turn off the printer.
18
Chapter 3
DIP switch settings
Although the factory settings are best for almost all users, if you have special
requirements, you can change the DIP switch.
3-1. Setting the DIP switches
• DIP switch functions
Your printer has two sets of DIP switches.
The functions of the switches are shown in the following table.
DIP - SW1
Switch
Function
ON
OFF
Default
1-1
OFF
1-2
Emulation Selection
Refer to the following table
OFF
1-3 Auto
cutter Enable Disable
OFF
1-4
Cartridge
one cartridge
two cartridges
OFF
1-5 Density
*1)
Bold
Normal
OFF
1-6 Special
Function
*2)
Enable Disable OFF
1-7
Near end sensor
Enable
Disable
OFF
1-8 Low
ink
check Disable Enable OFF
1-1
1-2
EPSON OFF
OFF
STAR OFF
ON
CITIZEN ON
OFF
EPSON-KP
*3)
ON ON
DIP - SW2 (RS232C Serial interface model)
Switch
Function
ON
OFF
Default
2-1
Data receive error
Print “?”
Ignore
OFF
2-2 Reserved OFF
2-3 Hand
Shaking
DTR/DSR XON/XOFF OFF
2-4 Word
length
7bit
8bit OFF
2-5 Parity
check Enable Disable OFF
2-6 Parity
selection
EVEN
ODD OFF
2-7
OFF
2-8
Baud rate selection
Refer to the following table
OFF
DIP - SW2 (Parallel interface model)
Switch
Function
ON
OFF
Default
2-1
Auto Line Feed
Enable
Disable
OFF
2-2
OFF
2-3
OFF
2-4
OFF
2-5
OFF
2-6
OFF
2-7
OFF
2-8
Undefined