Siemens OPTIPOINT 500 User Manual
Page 68
IP Adapter
Nur für den internen Gebrauch
P31003-E8400-A100-3-7620
7-4
Service Manual
Connection to the System
7.3
Connection to the System
Figure 7-3
Overview: connecting an optiPoint IPadapter to the system
Connect the optiPoint IPadapter to the Hicom system in the following sequence (please also
note the diagram "Electrical connection of the optiPoint IPadapter"):
1.
First of all, connect the U
P0/E
port of the IPadapter to the Hicom system (SLMO board).
Use the cable supplied with RJ-11 Mini-Western connectors (point 1).
2.
Connect the IPadapter to the LAN network. Use the LAN network cable (max. 3 m) sup-
plied for this (cable features 3 RJ-45 Mini-Western connector (point 2)).
The optiPoint IPadapter can be operated as a desktop unit or can be mounted on the wall with
a screw. The wall attachment can be found on the back of the IPadapter (point 3).
Figure 7-4
Electrical connection of the optiPoint IPadapter
PIN assignments on the IPadapter
Connector/ jack
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
U
P0/E
RJ11
NC
DC-
a(U
P0/E
) b(U
P0/E
)
DC+
NC
LAN
RJ 45
TDX+
TCD-
RXD+
NC
NC
RXD:
NC
NC
Table 7-1
Pin assignment
1
2
Hicom/
HiPath
(SLMO
board)
LAN - I/F
10 Base T
U
P0/E
optiPoint
IPadapter
1
2
3