Private Network Termination Units

Nur für den internen Gebrauch

P31003-E8400-A100-3-7620

4-2

Service Manual

PNT Private Network Termination

4.1

PNT Private Network Termination

PNT converts the two-wire U

P0

interface to the four-wire S

0

interface and extends the range.

This gives you the advantages of the S

0

and S

0

bus interfaces at great distances from the Hi-

com system (connecting up to eight telephones and using fewer cables and system ports).
The desktop model can also be mounted on the wall. Power is supplied by an optiset E local
power supply unit.

4.2

PNT E Private Network Termination

The PNT E converts the two-wire U

P0/E

interface to the S

0

interface to connect up to two S

0

terminals (such as a PC and fax) to Hicom.
A local power supply is available for the PNT E if the connected devices need to receive power
from the S

0

interface.

4.3

PNT Q Private Network Termination

PNT Q converts the two-wire U

2B1Q

interface to the four-wire S

0

interface and extends the

range. This gives you the advantages of the S

0

and S

0

bus interfaces at great distances from

the Hicom system (connecting up to eight telephones and using fewer cables and system
ports).

4.4

Distance Adapter (UCON S and M) at Hicom 300/300 E and HiPath
4000

Distance adapters increase the optiPoint 500 telephone range from 1,000 m to a total of 8,000
m, depending on the cable type. The range between the optiPoint 500 distance adapter and
telephone is limited to 100 m (depending on the cable type and diameter).
To connect this adapter, an SLMQ line card (U

2B1Q

interface, 16 ports) with LAP-S and CorNet-

TS must be provided in Hicom 300/300 E.
Power is supplied to the distance adapter via a local power supply unit. An 8-pin RJ 45 plug is
used as the mains power supply. This is the same as the plug used for PNT.
The stacked UCON S or M housing is suitable for desktop installation or mounting on the wall.

Distance Adapter S (single) - UCON S

UCON S has a 6-pin RJ 11 entry and exit port. It serves as the connection between an optiPoint
500 telephone and its options via the U

2B1Q

interface (2-wire).

Distance Adapter M (multiple) - UCON M

UCON M is available via four 6-pin RJ 11 entry (4x U

2B1Q

) and exit interfaces (4x U

P0/E

). This

adapter is used for connecting four telephones and their options.