beautypg.com

Siemens OPTIPOINT 500 User Manual

Page 41

background image

P31003-E8400-A100-3-7620
Service Manual

3-5

Nur für den internen Gebrauch

Startup

Telephone Tests

if no power is being supplied, the pattern is not discernible in the display window.

Test Function Not Working

If the test function does not work, you may need to connect an additional power supply unit to
the telephone.
If the date and time do not appear on the screen after startup, either the telephone or the line
is defective.

HiPath 4000/Hicom 300H

optiPoint 500 telephones on Hicom 300 H are recognized as optiset E IDs.

Only HiPath 4000 V1.0 and later recognize the optiPoint 500 IDs.

HiPath 3000/Hicom 150 H

The location of the Service key and the code assignments can be freely programmed in Hicom
150 H.

optiPoint 500 telephones are not recognized automatically by HiPath 3000 V3.0/V3.0 and ear-
lier and Hicom 150 H; instead they are treated like optiset E telephones. optiPoint 500
advance telephones are not released for sale on HiPath 3000 Version 3.0 and earlier. Only
HiPath 3000 V3.0 and later fully support the optiPoint 500 IDs.

optiPoint 500 telephone

Generation/recognition by Hicom 300 H

optiPoint 500 entry

--> optiset E basic

optiPoint 500 economy

--> optiset E advance

optiPoint 500 basic

--> optiset E advance plus/comfort

optiPoint 500 standard

--> optiset E advance plus/comfort

optiPoint 500 advance

--> optiset E advance plus/comfort + optiset E key module

optiPoint 500 telephone

Generation/recognition by HiPath 3000/Hicom 150 H and
HiPath 3000 Manager E/Hicom Assistant E Office

optiPoint 500 entry

--> optiset E basic

optiPoint 500 economy

--> optiset E advance

optiPoint 500 basic

--> optiset E advance plus/comfort

optiPoint 500 standard

--> optiset E advance plus/comfort

optiPoint 500 advance

--> optiset E advance plus/comfort + optiset E key module