Configuration of serial interface, Java commands, Restrictions – Siemens TC65 User Manual
Page 28: Flash file system, Memory
TC65 JAVA User's Guide
Strictly confidential / Released
s
TC65 JAVA User's Guide_V05
Page 28 of 90
26.09.2005
5.7.4
Configuration of Serial Interface
While a Java application is running on the module, only the AT Command API is able to
handle AT commands. All AT commands referring to a serial interface are ignored. In
particular these commands:
• AT+IPR
• AT\Q3
If Java is running, the firmware will ignore any settings from these commands. Responses to
the read, write or test commands will be invalid or deliver “ERROR”.
Note: When a Java application is running, all settings of the serial interface are done with the
class CommConnection. This is fully independent of any AT commands relating to a serial
interface.
5.7.5 Java
Commands
There is a small set of special Java AT commands:
• at^sjra, start a Java application
• at^sjnet, configuration of Java networking connections
• at^sjotap, start and configuration of over the air provisioning
• at^sjsec, security configuration
Refer to the AT command set [3].
5.8 Restrictions
5.8.1
Flash File System
The maximum length of a complete path name, including the path and the filename, is limited
by the Flash file system on the module to 124 characters. It is recommended names of
classes and files be distinguished by more than case sensitivity.
5.8.2 Memory
The CLDC 1.1 HI features a just-in-time compiler. This means that parts of the Java byte
code which are frequently executed are translated into machine code to improve efficiency.
This feature uses up RAM space. There is always a trade off between code translation to
speed up execution and RAM space available for the application.