Installing and Starting the Ethernet CP with STEP 7

50

SIMATIC NET NCM S7 for Industrial Ethernet

C79000-G8976-C129–06

Note

You can open the dialog for setting the interface at any time from the Properties
dialog of the CP in the “General” tab.

1. If you have not yet created a subnet in the project or have not yet created the

selected subnet, you can now create a subnet. To do this, select the “New”
button.

Result: An object of the type network is created in the project.

2. Check the addresses and if necessary change them. The system enters the

next free address automatically.

You will find detailed information on the address ranges in the online help.
Please note the following additional information:

– MAC address

The latest Ethernet CPs are supplied with a default MAC address (address
printed on the module). To be sure that you have a unique address
assignment, do not enter a MAC address in the configuration (the option is
deactivated). This means that the module automatically uses the factory–set
address. If you want to use ISO services, we recommend that you enter the
address printed on the module in the configuration.

Note

The ”IP address” and ”Subnet mask” input fields have no significance for ISO
transport (option ”IP protocol being used”).

3. Select the required subnet type in the “Subnet” list box.

4. You can display the properties dialog box for the selected subnet by clicking the

Properties button.

5. Enter information specific to the subnet node in the “General” tab.

6. You must finally confirm your input with OK, otherwise the networking is not

entered (refer to Point 3.).

Result: The CP is now configured as a network node for the corresponding S7
station.