Sanyo KHH2672R / CH2672R User Manual
Page 44

1
2
3
4
5
6
I-40
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
KHH2672R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 V, 5 A
Fan
Cross-flow
Number ... Dia. and length
in.
(mm)
1 ... O.D. 4-1/3 (110), L39 (990)
Fan motor
Model
UF4Q - 31A6P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole ... r.p.m. (230 V, High)
rpm
4 ... 1,277
Nominal output
W
30
Coil resistance
Ω
BRW - WHT
: 197.2
,
ORG - YEL
:
59.1
(Ambient temperature 68
°F)
WHT - VLT
:
41.4
,
YEL
- PNK
:
48.8
VLT
- ORG
:
22.2
,
Safety device
Operating temperature
Open
°F
248
±
9
Close
°F
171
± 27
Run capacitor
VAC,
µF
440 V , 1.8
µF
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows ...
3 ... 12.7
Face area
ft.
2
(m
2
)
2.57 (0.24)
Louver Motor
Model
M2EA24ZA01
Rating
208 to 230 V, 60 Hz
No. of pole ... rpm
8 ... 3
Output
W
2.5
Coil resistance (Ambient temperature 68
°F)
k
Ω
16.45
± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE
Heater Element (Aux. Heater)
Model
AH - KH2412
1.8 / 1.5
Input (230 / 208 V)
KW
Protective thermostat
OFF 140
± 5°F, ON 113 ± 9°F
Thermo fuse
Cut - off 370 + 2, - 5
°F, 277V - 15A