Sanyo KHH2672R / CH2672R User Manual
Page 40

1
2
3
4
5
6
I-36
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
UH3672R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 V, 5 A
Fan (Number … diameter)
in.
(mm)
Centrifugal (4 ... 5-29/32(150))
Fan motor
Model
KFG4X - 141A6P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole ... r.p.m. (230 V, High)
rpm
4 ... 940
Nominal output
W
100
Coil resistance
Ω
BRW - WHT
:
39.9
,
ORG - YEL
:
9.37
(Ambient temperature 68
°F)
WHT - VLT
:
6.91
,
YEL
- BLK
:
8.86
VLT
- ORG
:
11.4
,
BLK
- PNK
:
14.3
Safety device
Operating temperature
Open
°F
266
± 14.4
Close
°F
174.2
± 27
Run capacitor
VAC,
µF
440 V , 5
µF
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows ... Fins per inch
3 ... 12.7
Face area
ft.
2
(m
2
)
3.32 (0.308)
DATA SUBJECT TO CHANGE WITHOUT NOTICE