Sanyo KHH2672R / CH2672R User Manual
Page 43

1
2
3
4
5
6
I-39
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
KH3672R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 V, 5 A
Fan
Cross-flow
Number ... Dia. and length
in.
(mm)
1 ... O.D. 4-13/18 (120), L46 (1,170)
Fan motor
Model
SFG4Q - 41B6P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole ... r.p.m. (230 V, High)
rpm
4 ... 1,273
Nominal output
W
50
Coil resistance
Ω
GRY - WHT
: 122.3
,
ORG - YEL
:
23.03
(Ambient temperature 68
°F)
WHT - VLT
:
15.98
,
YEL
- PNK
:
9.272
VLT
- ORG
:
11.93
,
Safety device
Operating temperature
Open
°F
266
± 14.4
Close
°F
174.2
± 26
Run capacitor
VAC,
µF
440 V , 4
µF
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows ... Fins per inch
3 ... 12.7
Face area
ft.
2
(m
2
)
3.23 (0.3)
Louver Motor
Model
M2EA24ZA01
Rating
208 to 230 V, 60 Hz
No. of pole ... rpm
8 ... 3
Output
W
2.5
Coil resistance (Ambient temperature 68
°F)
k
Ω
16.45
± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE