Sanyo KHH2672R / CH2672R User Manual
Page 34

1
2
3
4
5
6
I-30
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
TH2672R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 V, 5 A
Fan (Number … diameter)
in.
(mm)
Centrifugal (4 ... 5-1/8(130))
Fan motor
Model
SR4X - 51A6P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High)
rpm
1,179
Nominal output
W
31
Coil resistance
Ω
BRW - WHT
: 111.0
,
ORG - YEL
:
16.7
(Ambient temperature 68
°F)
WHT - VLT
:
35.4
,
BLK
- PNK
:
23.9
VLT
- ORG
:
13.4
,
YEL
- BLK
: 136.6
Safety device
Operating temperature
Open
°F
266
± 14.4
Close
°F
174.2
± 27
Run capacitor
VAC,
µF
440 V , 1.5
µF
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows … Fins per inch
3 … 14.9
Face area
ft.
2
(m
2
)
1.81 (0.168)
Auto louver motor
Model No.
MT8 - 3C
Auto louver motor … Rated
V, W, rpm
240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77
°F)
Ω
16,430
Ω ± 8 %