Sanyo KHH2672R / CH2672R User Manual
Page 39

1
2
3
4
5
6
I-35
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
UH2672R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 V, 5 A
Fan (Number … diameter)
in.
(mm)
Centrifugal (4 ... 5-29/32(150))
Fan motor
Model
KFG4X - 71B6P
Source
230 - 208 V / 1 phase / 60 Hz
No. of pole … r.p.m. (230 V, High)
rpm
4 ... 920
Nominal output
W
100
Coil resistance
Ω
BRW - WHT
:
74.7
,
ORG - YEL
:
9.59
(Ambient temperature 68
°F)
WHT - VLT
:
19.1
,
YEL
- BLK
:
10.52
VLT
- ORG
:
10.5
,
BLK
- PNK
:
21.72
Safety device
Operating temperature
Open
°F
266
± 14.4
Close
°F
174.2
± 27
Run capacitor
VAC,
µF
440 V , 5
µF
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows … Fins per inch
3 … 14.9
Face area
ft.
2
(m
2
)
2.03 (0.189)
DATA SUBJECT TO CHANGE WITHOUT NOTICE