Sanyo KHH2672R / CH2672R User Manual
Page 38

1
2
3
4
5
6
I-34
SM831148
1. Specifications
1-2 Major Component Specifications
(A) Indoor Unit
MODEL No.
THH3672R
Source
230 - 208 V / 1 phase / 60 Hz
Remote controller (Option)
Wired or Wireless (See Unit Specification)
Controller P. C. B Ass'y
CR - TH2672
Control circuit fuse
250 V, 5 A
Fan (Number ... diameter)
in.
(mm)
Fan motor
Model
Source
No. of pole ... r.p.m. (230 V, High)
rpm
4 ... 1,015
Nominal output
W
100
Coil resistance
Ω
(Ambient temperature 68
°F)
Safety device
Operating temperature
Open
°F
266
± 14.4
Close
°F
174.2
± 27
Run capacitor
VAC,
µF
440 V , 4
µF
Heater Ass'y (Aux. Heater)
Model
AH - 2.4THS3632
2.4 / 1.94
Input (230 / 208 V)
KW
Protective thermostat
CS- 12AL OFF 122
± 6°F, ON 104 ± 10°F
Thermo fuse
SF96U Cut - off 205
± 4°F
Heat exchanger
Coil
Aluminum plate fin / Copper tube
Rows ... Fins per inch
3 ... 14.9
Face area
ft.
2
(m
2
)
3.51 (0.326)
Auto louver motor
Model No.
MT8 - 3C
Auto louver motor ... Rated
V, W, rpm
240 VAC , 3 W , 3 rpm
Coil resistance (Ambient temperature 77
°F)
Ω
16,430
Ω ± 8 %
DATA SUBJECT TO CHANGE WITHOUT NOTICE
BRW - WHT
:
61.05
,
ORG - YEL
:
13.23
WHT - VLT
:
9.955 ,
YEL
- BLK
:
19.25
VLT
- ORG
:
9.576 ,
BLK
- PNK
:
10.81
Centrifugal (4 ... 5-29/32(150))
KFG4X - 101C6P
230 - 208 V / 1 phase / 60 Hz