Sanyo KHH2672R / CH2672R User Manual
Page 20

1
2
3
4
5
6
I-16
SM831148
1. Specifications
1-1 Unit Specifications
Concealed-Duct Type
Cooling:
Rating conditions (*) : Room temperature 80 °F DB / 67 °F WB, Ambient temperature 95 °F DB / 75 °F WB
Heating:
Rating conditions (*) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 47 °F DB / 43 °F WB
Low temp conditions (**) : Room temperature 70 °F DB / 60 °F WB, Ambient temperature 17 °F DB / 15 °F WB
Indoor Unit
UH3672R
Outdoor Unit
CH3672R
POWER SOURCE
230 - 208 V / 1 Phase / 60 Hz
PERFORMANCE
Cooling
Heating
Capacity * [minimum~muximum]
BTU / h
31,200 [9,500~31,200]
36,200 [8,000~36,200]
(17˚F)**
BTU / h
20,200
Moisture removal (High)
Pints / h
10.0
Air circulation (H / M / L) 230 V
CFM
670 / 530 / 460
External Static Pressure
in. WG
0.24:at shipment / 0.4:using jumper cable
S.E.E.R. / H.S.P.F. (Region 4)
BTU / Wh
13.9
8.7
ELECTRICAL RATINGS
Voltage rating
V
230
208
230
208
Available voltage range
V
VAC 187 - 253
VAC 187 - 253
Max. Running amperes*
A
18.6
20.6
15.9
17.6
Power input
W
3,920
3,920
3,340
3,340
(17˚F)**
W
2,570
2,570
Back-up Heater
kW
Maximum overcurrent protection (Indoor/Outdoor)
A
15 / 35
Controls
Microprocessor
Low ambient control
Built-in 0˚F
Fan speeds Indoor / Outdoor
3 and Automatic control / Variable
Optional Wired Remote Controller
Optional Wireless Remote Controller
RCS-BH80UA. WL
Air deflection (Horizontal / Vertical )
Air filter
Drain pump (Drain connection)
Max.head 2-33/64 in. above drain connection (25A , OD32mm)
Compressor
Rotary(SANYO)
Operation sound
Indoor - Hi/Me/Lo
dB - A
38 / 33 / 31
Outdoor - Hi
dB - A
52
Refrigerant control
Electronic Expansion Valve (MOV)
REFRIGERANT TUBING
Limit of tubing length
ft. (m)
165 (50)
Limit of tubing length at shipment
ft. (m)
10~100 (3~30)
Limit of elevation difference
ft. (m)
Outdoor unit is higher than indoor unit : 100 (30)
between the two units
ft. (m)
Outdoor unit is lower than indoor unit : 50 (15)
Refrigerant tube
Narrow tube
in. (mm)
3 / 8 (6.35)
outer diameter
Wide tube
in. (mm)
5 / 8 (15.88)
Refrigerant amount at shipment
lbs. (kg)
6.17 (2.8) - R410A
DIMENSIONS & WEIGHT
Indoor unit
Outdoor unit
Unit dimensions
Height
in. (mm)
12-7/32 (310)
30- 23/32 (780)
Width
in. (mm)
58-9/32 (1,480)
37 (940)
Depth
in. (mm)
24-13/16 (630)
13- 3/8 (340)
Package dimensions
Indoor unit
Outdoor unit
Height
in. (mm)
14-3/32 (358)
34- 31/32 (888)
Width
in. (mm)
65-25/32 (1,671)
39- 31/32 (1,015)
Depth
in. (mm)
30-13/16 (783)
16- 3/32 (409)
Net weight
lbs. (kg)
104 (47)
143 (65)
Shipping weight
lbs. (kg)
115 (52)
161 (73)
Shipping volume
cu.ft. (m 3 )
16.5 0.468)
13.0 (0.369)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
FEATURES
MODEL No.
RCS-SH80UG / RCS-TM80BG