beautypg.com

Settings by telnet of the pc – JVC DM-NC40 User Manual

Page 55

background image

55

Operations

Connection

Connect the unit and PC using a network.

Ping command is available to test connection via network.

Example: If the IP address of the unit is 10.0.0.1 (factory set IP address)

1.

Start command prompt on the PC.

2.

Type “ping 10.0.0.1”.

3.

If setting and connection are correct, responses such as shown below will be displayed.

“Reply from 10.0.0.1: bytes: 32 time tieme<10ms TTL=64”

If there is some problem, the following timeout error will be displayed.

“Request timed out.”

Launching Telnet

Start telnet on PC

Example: When the IP address of the unit is 10.0.0.1 (factory set IP address)

1.

Start command prompt.

2.

Type “telnet 10.0.0.1”.

3.

Enter “nc40api” as the user name and “dm-nc40” as the password.

Settings by Telnet of the PC

Memo

When displayed lines in the telnet window are not enough, increase the buffer size in the settings of the Telnet

software.

Memo

If Telnet cannot be exited properly due to network or PC problems, reconnection of Tenet will fail since the unit

keeps previous Telnet connection. Reconnection will be possible in 10 minutes by timeout of previous telnet

connection.

Telnet can be disconnected by rebooting the unit.

Commands

Commands are the same for the terminal software. ( i

੬ See page 54)

Exiting Tenet

Enter “exit”.

Memo

When restarting from Telnet, the Telnet connection will be disconnected.

To continue operation from Telnet, perform the connection procedure again after the unit reboot.