4 serial ports and alarm port, Serial ports and alarm port, Step 1 – JVC DM-NC40 User Manual

Page 18: Connection/installation, Continued)

background image

18

1-4 SERIAL Ports and ALARM Port

Signal names of SERIAL ports and ALARM port located on the back of the unit are shown

below.

Step 1

Connection/Installation

(Continued)

[SERIAL 1, 2] Serial ports 1, 2

(Dsub 9-pin, male)

When viewing from the back of unit

SERIAL 1 port

(when set to RS232C)

SERIAL 2 port

[ALARM] input port for alarm and output port for control

(Dsub 15-pin, female)

Pin no.

Signal name

1

NC

2

RXD

3

TXD

4

NC

5

GND

6

NC

7

NC

8

NC

9

NC

SERIAL 1 port

(when set to RS485)

Pin no.

Signal name

1

NC

2

RX –

3

TX –

4

NC

5

GND

6

NC

7

TX +

8

RX +

9

NC

For detailed setup concerning the SERIAL ports,
੬ see “Serial Port Setup screen”, page 40)

When viewing from

the back of unit

Pin no.

Signal name

1

OUTPUT 1

2

OUTPUT 2

3

OUTPUT 3

4

OUTPUT 4

5

OUTPUT 5

6

OUTPUT 6

7

OUTPUT 7

8

OUTPUT 8

9

INPUT 1

10

INPUT 2

11

INPUT 3

12

INPUT 4

13

GND

14

GND

15

GND

Alarm input port

Signal length setting (

੬ Trigger Duration, page 38)

Polarity setting (

੬ Trigger, page 38)

Connection to 5V power, 10k

internally

Current of 10mA or less for input terminal

Open collector output equivalent

Polarity setting (

੬ OutputPin 1 ~ 8, page 39)

External connection capacity: DC5V, 10mA

Output terminal

Unit

Alarm input port

Example of sensor

INPUT
1~4

OUT

R

DC5V

Alarm input equivalent circuit

GND

GND

R

VCC

5V

Unit

Output terminal

Example of controlled device

OUTPUT
1~8

IN

R

DC5V

GND

GND