beautypg.com

Sample file modem_z.cfg – IBM Enterprise Server H80 Series User Manual

Page 208

background image

Sample File modem_z.cfg

#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP Z
#
# FUNCTIONS: Modem configuration file for many early Hayesᑍ compatible modems.
#

This example uses the ATZ reset command to choose the factory defaults.

#

This setup will work for many modems, but it is required for early vintage

#

modems which respond to neither the ATZ reset command nor the extended (&)

# commands. Refer to your modem manual.

#
# ᑍ Trademark of Hayes Microcomputer Products, Inc.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# If the modem has configuration switches, they should be set to the
# factory default settings.

ICDelay 1
DefaultTO 1
CallDelay 12

# AT Attention Code

,

Inserts delay in dialing commands

#

Z

Reset to factory defaults Q

Turn on responses

# E Turn echo off

Q1

Turn off responses

# V Use numeric responses

S =

Automatic answer inhibit

# +++

Escape to command mode

S =2 Answer on second ring

# H Hang-up

T = Tone mode. When used as T\r, it is a

#

no op to maintain program synchronization

#

when modem may/will echo the commands.

#

# %N Call-Out phone number

%P

Paging phone number

# %S Modem speed (available to users)

#
# Following are common responses from a wide range of modems:
# 16, 15, 12, 1 , 5 and 1 are connection responses.

Add others as required.

# 7=busy; 6=no dial tone; 4=error; 3=no carrier; 2=ring; =OK
#
# PROGRAMMING NOTE: No blanks between double quote marks (").

condout:

send "ATZQ T\r"

# Reset to factory defaults.

ignore " \r" or "OK\r\n" timeout 2

# Ignore modem response.

send "ATE T\r"

# Initialize modem: Echo OFF,

expect " \r" or "OK\r\n" timeout 2

#

Enable responses (Numeric),

send "ATQ V T\r"

#

Limit response codes.

expect " \r" timeout 2

# Confirm commands successful.

send "ATS = \r"

# Set AutoAnswer OFF

expect " \r" timeout 2

# Confirm command successful.

done

connect:

send "ATDT%N\r"

# Tone dialing command.
# %N from Call Home setup.

# Expect a connection response.

expect "16\r" or "15\r" or "14\r" or "12\r" or "1 \r" or "5\r" or "1\r" busy "7\r"

timeout 6

done

retry:

send "A/"

# Repeat the previous command.

# Expect a connection response.

expect "16\r" or "15\r" or "14\r" or "12\r" or "1 \r" or "5\r" or "1\r" busy "7\r"

192

RS/6000 Enterprise Server Model H80 Series User's Guide