Modem configuration sample files, Sample file modem_m0.cfg – IBM Enterprise Server H80 Series User Manual
Page 202

Modem Configuration Sample Files
Sample File modem_m0.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP: modem_m
#
# FUNCTIONS: Modem configuration file specifically for IBM 7852-4
#
modem with Auto-Reliable feature.
This feature must be turned off
#
for Catcher calls.
This example uses the AT&F reset command to
#
choose the factory defaults.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# The modem has configuration switches.
They should be set to the
# factory default settings, except switches 11 and 12.
These must be
# to UP ("AT" responses) and DOWN (Asynchronous operation), respectively.
ICDelay 1
DefaultTO 1
CallDelay 12
#
# %N Call-Out phone number
%R
Return phone number
#
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout:
send "AT&F&E2E T\r"
# Reset to factory defaults
# Reliable mode
# Echo off
ignore " \r" or "OK\r\n" timeout 2
# Ignore modem response.
send "AT&E12&E14\r"
# Disable pacing
# Disable data compression
expect " \r" or "OK\r\n" timeout 2
# Confirm commands successful.
send "AT&SF1&S S9=1\r"
# DSR independent of CD
# Force DSR on.
# CD respond time=1
ms
expect " \r" or "OK\r\n" timeout 2
# Confirm commands successful.
send "ATV S = \r"
# Numeric response code
# Auto-Answer off
expect " \r" or "OK\r\n" timeout 2
# Confirm commands successful.
done
connect:
send "ATDT%N\r"
# Tone dialing command.
# %N from Call Home setup.
186