MICOM-2ES/2RS/2TS ALE Supplement to Owner’s Guide

MNT

MultiNet: enable/disable the scanning of multiple ALE nets. When
enabled, this feature lets the radio communicate with stations in nets
other than the currently selected net.

MxCH Maximum Scan Channels: when MultiNet is enabled, the time needed

for scanning all the nets may be rather long. This parameter is used to
adapt the duration of the calling signal to the number of scanned net,
to ensure that communications are not disrupted.
You can use automatic selection, or select a specific value in the
range of 0 to 59 seconds.

ANY

AnyCall: enable/disable the sending of AnyCalls.

WILD Wildcard: enable/disable the sending wildcard calls.
AMD Automatic Message Display: enable/disable the sending of AMD

messages.

ILNK Inlink: enable/disable the inlink facility, which enables notifying

other call participants when each participant disconnects from the
link. All participants must be programmed to use the same selection
(either YES or NO).
Do not enable the inlink function when communicating with a radio
that does not support the full ALE capabilities in accordance with
MIL-STD-188-141B.

BDLK Bidirectional link: enable/disable the automatic setting up of a link on

the best channel after a bidirectional handshake with an individual
station.

The ALE options have the following factory-default values:

• PTT Timeout

No timeout

• Alert

Yes

• External Alarm

Yes

• Auto Address

No

• Quick Call

Yes

• Minimum LQA score 0
• Accept Link Timeout

Yes

• MNT

Yes

• MxCH

Auto

• ANY

Yes

• WILD

Yes

60