Minolta Magicolor 3100 Series User Manual
Page 387

Chapter 7 Wiring Diagrams and Signal Information
7-387
♦
Residual toner check circuit
In the residual toner check, four colors cannot be checked at a time but one color each is checked in
order.
Which color of residual toner is checked is selected with the NOTNR_CHK_
* signal, and the residual
toner is detected with the NOTNR_
* signal of the selected signal. The result is returned to the PWBA
HNB MCU using the NOTNR signal.
Signal line name
Description
SW TCRU_Y ON(L)+3.3VDC
SENSOR TCRU ASSY (Y) ON/OFF detection signal
The switch is ON when toner bottle is present.
SW TCRU_M ON(L)+3.3VDC
SENSOR TCRU ASSY (M) ON/OFF detection signal
The switch is ON when toner bottle is present.
SW TCRU_C ON(L)+3.3VDC
SENSOR TCRU ASSY (C) ON/OFF detection signal
The switch is ON when toner bottle is present.
SW TCRU_K ON(L)+3.3VDC
SENSOR TCRU ASSY (K) ON/OFF detection signal
The switch is ON when toner bottle is present.
NOTNR_Y
Residual toner detection signal by SENSOR TONER LOW (Y)
NOTNR_M
Residual toner detection signal by SENSOR TONER LOW (M)
NOTNR_C
Residual toner detection signal by SENSOR TONER LOW (C)
NOTNR_K
Residual toner detection signal by SENSOR TONER LOW (K)
NOTNR_CHK_Y
SENSOR TONER LOW (Y) selection signal in residual toner
check
NOTNR_CHK_M
SENSOR TONER LOW (M) selection signal in residual toner
check
NOTNR_CHK_C
SENSOR TONER LOW (C) selection signal in residual toner
check
NOTNR_CHK_K
SENSOR TONER LOW (K) selection signal in residual toner
check
NOTNR
Residual toner detection signal