78D0011

WDV Series Gas Fireplace

Burner FlaMe
The flames from the burner should
be visually checked as soon as the
heater i

s installed and periodically during

normal operation. In normal operation, at
full rate, and after operating for about 15
to 30 minutes, the flame should be yellow.
Figure 582
If the flame is blue and candle-like in
appearance, adjust glass or add more
glass over ports.
nOte: The type of installation, vent
system configuration, and wind effects
may cause the flame patterns to vary.

cleanInG anD MaIntenance

Burner, pIlOt anD cOntrOl cOMpartMent

Keep the control compartment, stones and burner areas surrounding
the stones clean by vacuuming or brushing at least twice a year. Make
sure the burner porting, pilot air opening and burner air opening are free
of obstructions at all times.

pIlOt FlaMe

The flames from the pilot should be visually checked as soon as the
heater is installed and periodically during normal operation. the pilot
flame must always be present when the fireplace is in operation.
Figure 51. The pilot flame has three distinct flames, one engulfing the
sensor, one engulfing the thermocouple, and the other reaching to the
main burner.

Burner

Inspect area around the injector. Remove any lint or foreign material
with a brush or vacuum.

W

arn

In

G

turn off gas before servicing fireplace. It is
recommended that a qualified service technician
perform these check-ups at the beginning of
each heating season

FP2453
hooded pilot flames

Figure 51 -
Pilot Flame

Thermopile

Sensor

FP2453

FP2436
WDV flame appearance

Figure 52 -
Burner Flame Appearance

FP2436