MK Diamond Products MK-370EXP User Manual
Page 40

GFCI
40
“Rodding" cooling channels is performed by inserting a small wire rod through the cooling inlet
on top of the Blade Guard and directing the rod out through each of the cooling flow tubes
located on the underside of the Blade Guard. The cooling channels should be “rodded" until all
ports are free of foreign debris.
NOTE:
(K)
Rod Cooling Channels and
recheck flow
BLADE STOPS TURNING
(B)
Check to see if the Ground
Fault Circuit Interrupter
(GFCI) is tripped
(A)
Verify all plugs are fully
installed
(C)
Verify circuit breaker at least
20 amps – if not, move to
20 amp circuit
(E)
Check power source voltage
is 115v – if not 115v, move to
another circuit
(D)
Verify circuit breaker not
tripped. If tripped, reset
once
MK-370EXP
MAINTENANCE & TROUBLESHOOTING