EXTERNAL WATER SOURCE
This is the preferred method of cooling.
19
WATER PUMP SETUP FOR OPERATION
The Water Pump can be setup for operation in two ways: External Water Source or Re-circulation.
RE-CIRCULATION
NOTE: When using the re-circulation method, the water should be changed often for longer pump life
(A)
Ensure that Cooling
Transfer Tube is connected
(D)
Fill the Water Pan until
water completely covers
the Water Pump suction
(B)
Place the Water Pump
toward the back of the
Water Pan
MK-370EXP
SETUP
(C)
Position pump as shown
and place the pump
electrical cord and cooling
transfer tube under the
frame.
NOTE: If cutting dry DO NOT connect the water pump.
1. Verify or remove the Drain Plug from the Water Pan.
2. Place the Water Pump in an external container.
3. Fill the external container until water completely covers the Water Pump suction inlet.
4. Place an external catch basin below the Water Pan drain hole.