Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual
Page 88
5 - 3
5. PARAMETERS
No.
Symbol
Name
Control
mode
Initial
value
Unit
Customer
setting
20
*OP2
Function selection 2
P S
0000
21
*OP3
Function selection 3 (Command pulse selection)
P
0000
22
*OP4
Function selection 4
P S
0000
23
FFC
Feed forward gain
P
0
%
24
ZSP
Zero speed
P S
50
r/min
25
For manufacturer setting
0
26
For manufacturer setting
100
27
*ENR Encoder output pulses
P S
4000
pulse
/rev
28
TL1
Internal torque limit 1
P S
100
%
29
For manufacturer setting
0
30
For manufacturer setting
0
31
MO1
Analog monitor 1 offset
P S
0
mV
32
MO2
Analog monitor 2 offset
P S
0
mV
33
MBR
Electromagnetic brake sequence output
P S
100
ms
34
GD2
Ratio of load inertia moment to servo motor inertia moment
P S
70
0.1
times
35
PG2
Position loop gain 2
P
35
rad/s
36
VG1
Speed loop gain 1
P S
177
rad/s
37
VG2
Speed loop gain 2
P S
817
rad/s
38
VIC
Speed integral compensation
P S
48
ms
39
VDC
Speed differential compensation
P S
980
40
For manufacturer setting
0
41
*DIA
Input signal automatic ON selection
P S
0000
42
*DI1
Input signal selection 1
P S
0002
43
*DI2
Input signal selection 2 (CN1-4)
P S
0111
44
*DI3
Input signal selection 3 (CN1-3)
P S
0882
45
*DI4
Input signal selection 4 (CN1-5)
P S
0995
46
*DI5
Input signal selection 5 (CN1-6)
P S
0000
47
*DI6
Input signal selection 6 (CN1-7)
P S
0000
48
*LSPN LSP LSN input terminals selection
P S
0403
E
xp
ansi
on
p
ara
m
et
ers
1
49
*DO1 Output signal selection 1
P S
0000