Parameters – MITSUBISHI ELECTRIC MR-E- A/AG User Manual
Page 109

5 - 24
5. PARAMETERS
Class
No.
Symbol
Name and function
Initial
value
Unit
Setting
range
Control
mode
73
SC5
Internal speed command 5
Used to set speed 5 of internal speed commands.
300
r/min 0 to in-
stanta-
neous
permi-
ssible
speed
S
74
SC6
Internal speed command 6
Used to set speed 6 of internal speed commands.
500
r/min 0 to in-
stanta-
neous
permi-
ssible
speed
S
75
SC7
Internal speed command 7
Used to set speed 7 of internal speed commands.
800
r/min 0 to in-
stanta-
neous
permi-
ssible
speed
S
76
TL2
Internal torque limit 2
Set this parameter to limit servo motor torque on the assumption
that the maximum torque is 100[%].
When 0 is set, torque is not produced.
When torque is output in analog monitor output, this set value is the
maximum output voltage ( 8V).
100
%
0
to
100
P S
77
00
78
10000
79
10
80
10
81
100
82
100
83
100
Ex
pan
si
on
par
ame
te
rs
2
84
For manufacturer setting
Don’t change this value by any means.
0000