beautypg.com

MITSUBISHI ELECTRIC MR-E- A/AG User Manual

Page 278

background image

15 - 33

15. MR-E- AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT

Class

No.

Symbol

Name and function

Initial

value

Unit

Setting

range

Control

mode

2

ATU

Auto tuning

Used to selection the response level, etc. for execution of auto tuning.
Refer to Chapter 7.

Auto tuning response level setting

If the machine hunts or generates
large gear sound, decrease the
set value.
To improve performance, e.g.
shorten the settling time, increase
the set value.

Set

value

Response

level

1

Low

response

Middle

response

High

response

Gain adjustment mode selection
(For more information, refer to Section 7.1.1.)

Machine resonance
frequency guideline

15Hz

2

20Hz

3

25Hz

4

30Hz

5

35Hz

6

45Hz

7

55Hz

8

70Hz

9

85Hz

A

105Hz

B

130Hz

C

160Hz

D

200Hz

E

240Hz

F

300Hz

Set

value

Gain adjustment mode

0

Description

1

3

Simple manual adjustment.

4

Manual adjustment of all gains.

Interpolation mode

Fixes position control gain 1
(parameter No. 6).

Auto tuning mode 1

Fixes the load inertia moment
ratio set in parameter No. 34.
Response level setting can be
changed.

Manual mode 1
Manual mode 2

2

Auto tuning mode 2

Ordinary auto tuning.

0

0

0105

Refer to
Name
and
function
column.

S

3

1

4

1

5

For manufacturer setting
Don’t change this value by anymeans.

100

6

PG1

Position loop gain 1

Used to set the gain of position loop.
Increase the gain to improve trackability in response to the position
command.
When auto turning mode 1,2 is selected, the result of auto turning is
automatically used.
To use this parameter, set " 1 " to parameter No. 20 to validate
servo lock at stop.

35

S

B

asi

c p

ara

m

et

ers

7

For manufacturer setting

Don’t change this value by anymeans.

3