13. OPTIONS AND AUXILIARY EQUIPMENT

Encoder cable of 30m or more

POINT

The communication system of the encoder cable in this wiring diagram is
the four-wire type. Set "1 " in parameter No. 20.

When fabricating an encoder cable, use the MR-ECNS (IP20-compatible model) or MR-ENECNS
(IP65/IP67-compatible model) connector set. Referring to the following wiring diagram, you can
fabricate an encoder cable of up to 50m.

MRR

P5

LG

1

2

MR

3

4

MDR

8

B

F

S

A

MD

7

9

SD

C

D

R

N

MR-ESCBL30M-H
MR-ESCBL40M-H
MR-ESCBL50M-H

MR-ENECBL30M-H
MR-ENECBL40M-H
MR-ENECBL50M-H

P5G

MR

MRR

MDR

MD

SHD

P5E

M CONT

Servo amplifier side

Encoder side

Plate

(Note)