86D0024

PRODuCT FEATuRES and SPECIFICATIONS

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maxi-

mum of 10

1

/

2

" W.C. on natural gas systems operating at higher pressure.

MILLIVOLT
Regulator Pressure Setting: 3.5" w.c.
Pilot Regulator:

3.5" w.c.

Gas Inlet Pressure:

Max 10

1

/

2

" w.c.

Min. 5" w.c.

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a

maximum of 13" w.c.
MILLIVOLT
Regulator Pressure Setting: 10" w.c
Gas Inlet Pressure:

Max. 13" w.c.

Min. 11" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of matches or batteries.
Millivolt control has three (3) positions:

OFF

- All gas to the gas logs is shut off at the valve.

IGN

- Valve position to light/maintain a standing pilot.

ON

- Valve position to turn ON/OFF log set with remote switch/thermostat.

PILOT/ODS

The gas log heater is fitted with a specially designed safety pilot (ODS assembly) which

senses the amount of oxygen available in the room and shuts the gas log heater off if the

oxygen level begins to drop below a satisfactory level. The pilot can only be relit when

adequate fresh air is available.

THERMAL GENERATOR

The millivolt gas log pilot is fitted with a Millivolt (thermopile) generator to provide power

for remote activation.

Gas Rate

Model Number Control Max. BTu/hr Min. BTu/hr

MJ27NR

Millivolt

38,000

25,500

Gas Rate

Model Number Control Max. BTu/hr Min. BTu/hr

MJ27PR

Millivolt

37,000

29,500