TROUBLESHOOTING

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and

the heater may backfire when lit. If the gas quality or pressure is low, contact your local

gas supplier immediately.

W

ARNING

OBSERvED PROBLEM POSSIBLE CAuSE

REMEDY

ODS/pilot lights, but flame

goes out when control

knob is released.

1. Control knob not fully pressed in.

1. Press in control knob fully.

2. Control knob not pressed in long

enough.

2. After ODS/pilot lights, keep control knob

pressed in for 30 seconds.

3. Manual shutoff valve not fully open.

3. Fully open manual shutoff valve.

4. Thermocouple connection loose at

control valve.

4. Hand tighten thermocouple connection

until snug, then tighten 1/4 turn more.

5. Pilot flame not touching thermocouple,

which allows thermocouple to cool,

causing pilot flame to go out. This

problem could be caused by either

low gas pressure, or a dirty or partially

clogged ODS/pilot.

5. Contact local gas company.

6. Thermocouple damaged.

6. Replace thermocouple.

7. Control valve damaged.

7. Replace control valve.

Burner does not light after

ODS/pilot is lit.

1. Burner orifice is clogged.

1. Burner orifice is clogged.

2. Burner orifice diameter is too small.

2. Burner orifice diameter is too small.

3. Inlet gas pressure is too low.

3. Inlet gas pressure is too low.

Burner backfires during

combustion

1. Manifold pressure is too low.

1. Contact local gas company.

2. Burner orifice is clogged.

2. Clean burner or replace burner orifice.

Slight smoke or odor

during initial operation.

1. Burner orifice is clogged or damaged.

1. Clean burner or replace burner orifice.

2. Burner is damaged.

2. Replace burner.

3. Gas regulator defective.

3. Replace gas regulator.

Logs appear to smoke

after initial operation.

1. Vapors from paint or curing process of

logs.

1. Problem will stop after a few hours of

operation. Run the heater with the damper

open if you have one, or open a window

for the first few hours.

2. Log heater is intended to be smokeless.

Turn OFF heater and call qualified service

person.

H e a t e r p r o d u c e s a

whistling noise when

burner is lit.

1. Turning control knob to HIGH position

when burner is cold.

1. Turn control knob to LOW position and let

warm up for a minute.

2. Air in gas line.

2. Operate burner until air is removed from

line. Have gas line checked by local gas

company.

3. Dirty or partially clogged burner orifices. 3. Clean burner or replace burner orifice.

No gas to pilot.

1. LP-regulator shut down due to inlet

pressure too high.

1. Verify LP tank regulator is installed and

set at 11" to 13" w.c.

2. Replace regulator on heater.