13

FP1998
heat resist mantel

Hood

Heater in

Fireplace or

Firebox

8" or More of

Heat Resis-

tant Materials

FP1998

CLEARANCES and HEIGHT REQUIREMENTS

Figure 6 - Measuring Heat Resistant Material for Mantel

Heat resistant material (minimum requirements) with wooden mantel or other combustible projection:
To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat

resistant material shown in Figure 6, then refer to Table B.

TABLE B - Heat Resistant Material Heights and Mantel Location

Heat Resistant

Requirements for Safe Installation with Wood

Material

Mantel, Shelf or Other Combustible Projection

Measurement

MJ27

12" or more

Hood not required. Observe profile (side elevations)

shown on Page 14, Figure 8.

8" to less than 12"

Install hood and observe profiles shown on Page 14,

Figure 7;

OR extend heat resistant material to at least

12" and observe profiles shown on Page 14, Figure 8.

Less than 8"

Extend heat resistant material to at least 8", install

hood and observe profiles shown on Page 14, Figure

7;

OR extend heat resistant material to at least 12"

and observe profiles on Page 14, Figure 8.